Batteries are a key component in a grid-tie with back-up or a stand-alone renewable energy
system that all of the other components rely on for operation. Without proper maintenance,
batteries can fail prematurely and shut the whole system down. However, toiling over your battery
bank with a voltmeter, hydrometer and a gallon of distilled water every day is not necessary.
With simple monthly and quarterly maintenance procedures, your batteries should last for a long time.
On the other hand, neglecting your batteries can drastically shorten their life span. The following
statement sums it up best, "few batteries die a natural death, most are murdered". The following
information is designed to tell you how to get the longest life and best performance possible from
your battery bank. Most of this information is for flooded cell lead-acid batteries; alkaline
(Ni-FE & Ni-Cad) and sealed gel-cell battery charging characteristics are completely different.
Top
Types Used in Solar Systems:
There are three types of batteries that are most popularly used in solar electric systems.
Each type has its pluses and minuses, so we will also include the systems the individual types
are best suited for.
Top
Flooded Lead Acid:
Flooded lead acid batteries have the longest track record in solar electric use and are
still used in the majority of stand-alone solar systems. They have the longest life and the
least cost per amp-hour of any of the choices. However the other side of the coin is, in order to
enjoy these advantages, they require regular maintenance in the form of watering, equalizing
charges and keeping the top and terminals clean. Some examples of flooded lead-acid batteries
used in solar electric systems are 6 volt golf-cart batteries, 6 volt L-16's and 2 volt
industrial cells for large systems.
Top
Absorbed Glass Mat Sealed Lead Acid (AGM):
AGM batteries are seeing more and more use in solar electric systems as their price comes down and as
more systems are getting installed that need to be maintenance free. This makes them ideally suited
for use in grid-tied solar systems with battery back-up. Because they are completely sealed they can't
be spilled, do not need periodic watering, and emit no corrosive fumes, the electrolyte will not
stratify and no equalization charging is required. AGM's are also well suited to systems that get
infrequent use as they typically have less than a 2% self discharge rate during transport and storage.
They can also be transported easily and safely by air. Last, but not least, they can be mounted
on their side or end and are extremely vibration resistant. AGM's come in most popular battery
sizes and are even available in large 2 volt cells for the ultimate in low maintenance large
system storage.
When first introduced, because of their high cost, AGM's were mostly used in commercial
installations where maintenance was impossible or more expensive than the price of the batteries.
Now that the cost is coming down they are seeing use in all types of solar systems as some of today's
owners think the advantages outweigh the price difference and maintenance requirements of flooded
lead acid batteries.
Top
Gelled Electrolyte Sealed Lead Acid:
Gelled lead acid batteries actually predated the AGM type but are losing market share to the AGM's.
They have many of the same advantages over flooded lead acid batteries including ease of
transportation, as the AGM type, except the gelled electrolyte in these batteries is highly viscous
and recombination of the gases generated while charging, occurs at a much slower rate. This means
that they typically have to be charged slower than either flooded lead acid or AGM batteries. In a
solar electric system you have a fixed amount of sun hours every day and need to store every solar
watt you can before the sun goes down. If charged at too high a rate, gas pockets form on the plates
and force the gelled electrolyte away from the plates, decreasing the capacity until the gas finds
its way to the top of the battery and is recombined with the electrolyte. For use in a grid-tie with
back up system or any system where discharge rates are less than severe, gel batteries could be a
good choice.
Top
Think of your batteries like a bucket of energy...
Batteries are simply a storage vessel for the direct current (DC) power produced from your charging
sources (solar modules, wind generator, micro-hydro or generator/battery charger). If you aren't
familiar with the water to electricity analogy, please read the Basics of Electricity section.
If you don't have time to read that whole section, then just remember that pressure = voltage and
flow rate = amperage. The size of the bucket determines how much water it will hold which is
analogous to the amp-hour storage capacity of a battery (bigger, heavier batteries hold more energy
like a larger bucket holds more water). If you connected a pressure gauge to the bottom of a bucket
and started filling it with water you would see the pressure increase until the water reaches the
top. The same holds true for a battery as you put amperage or current into it, the voltage level rises.
Top
Deep Cycle vs. Shallow Cycle
In battery lingo, a cycle on your battery bank occurs when you discharge your battery and then
charge it back up to the same level. A lead acid battery is designed to absorb and give up electricity
by a reversible electrochemical reaction.
How deep a battery is discharged is termed depth of discharge (DOD) while the state of charge (SOC)
is 100% minus the DOD. This means that a 25% DOD equals a 75% SOC. A shallow cycle occurs when
the top 20% or less of the battery's energy is discharged and then recharged. Automotive starting,
lighting and ignition batteries (SLI) are of the shallow cycle type and are not recommended for use
in a photovoltaic system. The lead plates inside an SLI battery are thin with a large overall surface
area. This design can produce a high amount of current in a very short time (which is ideal for
starting engines), but cannot be discharged very deeply without damaging them and/or shortening
their life span considerably.
Deep cycle batteries on the other hand can be repeatedly discharged to 80% DOD and recharged without
damaging them (although repeated deep cycling will shorten the battery's life as compared to the same
number of shallow cycles). Deep cycle batteries have thicker lead plates which have less overall
surface area as compared to an SLI battery. Because of the lessened availability of surface area for
chemical reaction, deep cycle batteries produce less current than a shallow cycle battery but can
produce that amount of current for a much longer period of time.
The depth of cycling has a good deal to do with determining a battery's useful life.
Even batteries designed for deep cycling are "used up" faster as the depth of discharge is increased.
It is common practice for a system to be designed with deep cycle batteries even though the daily
or average discharging amounts to a relatively shallow depth of discharge. To get the longest life
out of your battery bank, purchase deep cycle batteries and shallow cycle them.
Top
Warm in the winter, Cool in the summer
The speed of the charging and discharging chemical reactions occurring inside a lead-acid battery
is governed by temperature and charge/discharge current. The colder the temperature the slower the
reactions and conversely the warmer the temperature the faster the reactions. Hence a cold battery
will deliver less amperage in any given time frame as compared to a warm battery. Most of us have
experienced this effect when trying to start our cars on a cold morning; the engine just doesn't
turn over as quickly if at all. Warm that same battery up and you will see a major improvement.
(See the bar graph of temperature effects below). The optimum temperature for a lead-acid battery
is around 77°F, but 60-80°F is acceptable. For this reason we like to see batteries placed indoors
or in a heated and ventilated space to maintain them between 60° to 80°F. If you do install them in
an unheated space, battery capacity must be increased to compensate for this derating. On the other
extreme, high temperatures (110°F+) can drastically shorten the life of the battery and should be
avoided as well.
Top
Batteries aren't 100% efficient
Energy is never consumed or produced, it merely changes form. The efficiency of conversion is
never 100% and in the case of new batteries averages around 90%. This means that if you want to
discharge 100 watt-hours of energy from a battery you must charge it with approximately 110 watt-hours
of energy.
Due to impurities in the chemicals used for battery construction, batteries will lose power to local
action, an internal reaction which occurs whether you are using the battery or not. This slow
discharging is termed self-discharge and its rates vary greatly among battery types and increases
along with temperature. The rate also increases with the age of a battery, so much so that an
old battery may require significant amount of charging just to stay even. Even new batteries
may lose 1 to 2% of charge per day. Lead calcium grid batteries have the lowest self-discharge
rates, but are not designed for deep cycling applications.
Top
Determining battery state of charge
Battery state of charge is determined by reading the static (i.e. not charging or discharging)
battery voltage or the specific gravity of the electrolyte. The density or specific gravity of
the sulfuric acid (H2SO4) electrolyte of a lead-acid battery varies with the state of charge and
temperature. The density is lower when the battery is discharged and higher as the cells are charged,
(see the table below). This is because the electrolyte is part of the chemical reaction, it changes
as the chemical reaction takes place. Specific gravity is read with a hydrometer which will tell
the exact state of charge. A hydrometer cannot be used with sealed or gel-cell batteries.
Voltage meters are used to approximate battery state of charge. They are relatively inexpensive and
easy to use. The main problem with relying on voltage reading alone is the high degree of battery
voltage variation through the working day. Battery voltage reacts highly to charging and discharging.
In a PV system we are usually charging or discharging and many times are doing both at the same time.
As a battery is charged the indicated voltage increases and as discharging occurs, the indicated
voltage decreases.
These variations may seem hard to track, but in reality they are not. A good accurate digital meter
with a tenth of a volt accuracy can be used with success. The pushing and pulling of voltage, once
accounted for by experience, can also help indicate the amount of charging or discharging that is
taking place.
By comparing voltage readings to hydrometer
readings, shutting off various charging sources or loads and watching the resulting voltage changes,
the system owner can learn to use indicated voltage readings with good results.
Top
Monitoring & Maintenance:
Monitoring battery state of charge is the single largest responsibility of the system owner. The battery
voltage should be kept at or above a 50% state of charge at all times for maximum battery life
(see the battery voltage table). Be sure to keep the battery's electrolyte level at the marked full
level and never let the plates become exposed to the air. When refilling the batteries,
use only distilled water - not tap water. Water is the only element used by your battery, you should never
have to add additional acid to your battery. Do not over-fill the batteries or fill when the batteries are
discharged. Over-watering dilutes the acid excessively and electrolyte will be expelled when charging.
Top
Battery Gassing:
As batteries are charged they create bubbles of gas, produced when the chemical reaction cannot keep up with the
energy input. Some gassing is necessary in flooded cell batteries. The amount and duration of gassing varies
from one battery to another. Gassing mixes the electrolyte and compensates for the tendency of the electrolyte to
stratify with the more dense acid on the bottom. Gassing is the product of splitting water molecules into hydrogen
and oxygen. This consumes water and creates the need for its periodic replacement.
Top
Corrosion:
A slight acid mist is formed as the electrolyte bubbles upon charging. This mist is highly
corrosive, especially to the metallic connectors on the tops of the batteries. Inspect for
corrosion and carefully clean these periodically as needed with baking soda and water.
Be sure not to get any baking soda into the battery electrolyte as it will have a neutralizing
effect. Corrosion buildup can create a good deal of electrical resistance, which can contribute
to shortened battery life and the waste of power. It's always a good idea to wear goggles and
protective gear (goggles, rubber gloves and apron) when working on your batteries as the sulfuric
acid can seriously damage your eyes and eat holes in your clothes.
Top
Equalization (EQ):
Equalization is a controlled overcharging of a fully charged battery. This overcharge mixes the
electrolyte, evens the charge among varying battery cells and reduces permanent sulfation of the
battery plates. It is energy invested in lengthening the life of the battery. Though the PV system
battery bank receives a good deal of cycling and gassing through normal activity, equalization is a
complement to this activity and as a rule of thumb should be done every 60 to 90 days.
The equalization process consumes water and produces much gassing, so your batteries should be well
ventilated during this charging. Equalization charging voltages vary widely, as do duration times,
so the batteries should be monitored closely during this process. Check periodically during the EQ
process. You don't have to check every cell each time, but watch any that show a high variation from
the rest of the cells. Keep checking the specific gravity of the electrolyte until you receive three
readings of 30 minutes apart which indicate no further increase of specific gravity values. Keep a
record of individual cell voltages and specific gravity before and after equalizing. Equalization
will take your voltage to 15 volts or higher (30 volts on a 24 volt system) so make sure any DC
loads are disconnected before you begin.
Top
Battery Connections:
The connections from battery to battery and on to the charging and load circuits are critical.
Before connecting your batteries together, be sure that the interconnects and battery terminals
are clean. When making your series and parallel battery connections, be careful not to torque the
connecting hardware too tight as the battery's lead posts can break easily. After all battery
connections are made, go back to each battery terminal and apply anti-corrosion coating or grease
to minimize corrosion build up. Torquing all bolts equally avoids variations in resistance. This
variation in resistance is the main reason we prefer to minimize the number of parallel strings
in the bank. Higher resistance values on one string of batteries result in less charge to that
string and consequently shorter life. We also place the main negative and positive on opposing
corners of the battery bank. The goal is to keep the variation of resistance from one parallel
string to another to a minimum.
Top
Used Batteries:
Like most things, you get what you pay for. Used lead acid batteries, especially large two volt
telephone type cells can be found for sale at some very attractive prices. While used solar
modules and inverters are usually an acceptable risk, used batteries are not. Should you
consider them? In our experience it is difficult to know just how an older battery has been used
and cared for. Our recommendation on used batteries is to inspect them carefully in person, get
as much information as you can on them (manufacturer, age, amp-hour capacity and type of system
they were used in) and have them load tested. Without load testing used batteries you are really
guessing as to their remaining life. If you are considering telephone cells, realize that they
are normally shallow cycle lead calcium grid construction, and should not be used in a system
designed for deep cycling.
Top
DON'T SKIMP ON BATTERIES!
A correctly sized battery bank is vital to the proper functioning of your system.
Compromising on the battery bank can lead to poor performance and dissatisfaction with the
entire system. Do not skimp here.
Top
|